DRI-STEEM Vapor-logic3 to Vapor-logic4 Adaptor Board Installation Manual • Page 3
Figure 3-1:
GTS subpanel
VL3 main board* VL3 GTS expansion boards*
Top wire channelRibbon cables*
Keypad/display
cable
*
Not re-used
Removing Vapor-logic3, installing Vapor-logic4
1. If upgrading an outdoor GTS®, complete Steps 1 through 3 in “GTS
with outdoor enclosure” on Page 6 before proceeding.
2. Remove GTS control access panel to access the subpanel, shown in
Figure 3-1.
3. Disconnect Vapor-logic3 keypad/display cable and ribbon cables
from Vapor-logic3 main board and expansion board(s). Ribbon
cables will not be re-used.
4. Torque all terminal block screws to 2.5 in-lb (0.28 N·m) to prevent
wires from pulling loose in Step 5.
5. Mark location of Vapor-logic3 main board on subpanel by making
corner marks on subpanel with felt-tipped marker.
6. Use pliers to pull terminal blocks from Vapor-logic3 main board.
Unscrew stand-offs, and remove board and stand-offs (they will not
be re-used).
7. Leaving adhesive backing paper on the six nylon stand-offs
packaged with Vapor-logic4 adaptor board, push stand-offs into
adaptor board mounting holes, as shown in Figure 3-2.
WARNING
Shut down humidifier
Before performing any maintenance or
service procedures, shut off all electrical
power to humidifier using field-installed
fused disconnect, lock all power
disconnect switches in OFF position, and
close the gas shut-off valve.
GTS humidifiers:
Board removal and replacement
Figure 3-2:
VL4 adaptor board stand-offs
Bottom of VL4 adaptor board shown
Stand-off